Mini Futuro
We offer an innovative range of Mini futuro-3Ph. which has been
designed and developed in accordance with the needs of our clients.
Customized as per the specifications of our clients, this is a user
friendly auto mains failure
Solution for single phase generator sets. These have been manufactured
adopting Micro- controller technology to achieve reliable and accurate:
Start stop operation of DG set
Load changeover from DG and MAINS
Fault annunciation for safety of DG Set
Designed with reduced number of components, Mini- futuro For 1-Phase
model works on the terminal voltage of 12V or 24V. After sensing the
main supply, it starts giving pulses to Gen-Set starter (Start
Solenoid), when Mains Voltage (in-built) goes below the set limit.
Once the Gen-Set starts, there is developed a rated voltage and the
power is supplied to load from Gen-set. In case any fault occurs on the
engine side, Gen-set stops automatically, indicating the fault with a
respective fault LED & buzzer. Pressing the accept button, fault
can be acknowledged stopping the buzzer but the fault LED remains ON.
Accomplishing fault rectification and resetting the system, Gen-set
starts once again. Once the main supply is resumed, the load is
changed-over to mains and the DG Stop Contacts stops the engine after
pre decided idle run time which is settable on the front. No manual
mode operation required, however in case for manual operation, control
supply is disconnected and Gen-set is stared externally. Load change
over will happen without DC supply.
3 phase model has been designed for automatic DG start stop and fault
annunciation. Potential free contacts from any mains sensing device
such as (three phase voltage relay) carries on main sensing and the
load changeover is designed externally.
Special features:
Compact designs
Designed using latest Micro-controller technology
Simplest single phase AMF controller
MIMIC type of front fascia
Easy to use
INDICATIONS for main ON, Gen-set start & stop, Gen-set ON, Load
on mains/Get-set & all faults (Main fail, low lube oil pressure,
Battery low, Set fails to start, Alternator fail and low fuel)
Contactors not required for single phase application
Annunciation with flasher & buzzer both; including Accept, Reset & Test facility
Facility for connection of external Hooter
Design facilitates easy and quick installation
Maintenance Free
Existing non-AMF panels(standard panel)
Can be easily converted in to AMF panels using Mini-Futuro
Total wireless interiors
Manual Mode not required.
AMF-N96-3 Potential Free Contacts for all the faults for external integration.
|